- Warm up ATF liquid and switch off the engine.
|
- Turn out a drain stopper and lower ATF in in advance prepared capacity. Check a condition of ATF.
|
Jellied stopper of AT A5S 560Z
|
- Delay a drain stopper with new consolidation with the required effort and turn out a stopper of a jellied opening.
|
- At the switched-off engine fill AT with liquid so that it began to follow from a jellied opening.
- Start the engine, transfer the selector lever to situation "P". Turn on passing beam (the selector lever in situation "N").
- Again add ATF that it began to follow from a jellied opening. Then delay a stopper of a jellied opening with new consolidation and with the required effort.
- Squeeze out a brake pedal, set a winter operating mode of AT and translate the selector lever through all provisions. Check the AT level by means of the diagnostic unit.
- Approximately in 5 minutes of operation of the engine make sure of lack of leakages of ATF.
|