5-sistemy-okhlazhdeniya-dvigatelya-otopleniya-ventilyacii-i-kondicionirovaniya-vozdukha.html
5. Cooling systems of the engine, heating, ventilation and air conditioningSpecifications
Inclusion temperature//switching off of the coupling of the drive of the fan of the cooling system, °C |
|
90/60 |
- M60/1, M60/1, M62 engines (B 35, B 44)
|
95 ± 4//60 |
|
92 ± 4//60 |
|
102 ± 4//75 |
Side play of the bearing of the coupling of the drive of the fan of the cooling system, mm |
- M52, M52TU engines (at Ø of 120 mm)
|
± 0.65 |
- M60/1, M60/1, M62 engines (B 35, B 44) (at Ø of 156 mm)
|
± 0.65 |
- M62 B 46 and M73 engines (at Ø of 156 mm)
|
± 0.45 |
Temperature of the beginning of opening of the thermostat (it is beaten out on the thermostat), °C |
|
80 |
|
92 |
|
97 |
|
88 |
|
95 |
Consumption of current an additional heater at the maximum power, And |
Oil cooler volume, including hoses, l |
12.5 ± 1 |
|
0.75 |
|
1.0 |
Test pressure of the oil cooler, atm |
16 |
Test pressure of the cooling system of the engine, atm |
1.5 |
Test pressure of a radiator of the cooling system of the engine, atm |
|
2.0 |
- M51, M52, M60/1, M60/2, M62, M73 engines
|
1.5 |
Pressure of opening of the safety valve of excessive pressure of the cooling system, atm |
|
2+0.1
|
|
|
Depression of opening of the vacuum valve of the cooling system, atm |
0.1 |
K/V system
Coolant type |
R135a |
Amount of coolant, |
- To 12.1997 g of the issue (a big tank of a dehumidifier)
|
1210 ± 25 |
|
|
1210 ± 25 |
- M52, M57, M62, M73 engines
|
680 ± 10 |
|
700 ± 25 |
- L7 (without//with back To/in)
|
1270 ± 25//1400 ± 25 |
Pressure on an entrance//an exit of the K/V safety valve, atm |
14/1.8 |
Working pressure To/in, atm |
2 ÷ 35 |
Efforts of tightening of threaded connections, Nanometer
Drain stopper of OZh in the block of cylinders |
25 |
Cap nut of fastening of the coupling of the drive of the fan to the water pump |
40 |
Cooling system fan fixture to the driving coupling |
10 |
|
|