5-1-4-snyatie-i-ustanovka-rasshiritelnogo-bachka.html
5.1.4. Removal and installation of a broad tankModels with engines, except M57 and M67
|
- Lower cooling liquid only up to one point below than the level of a broad tank.
|
- Separate the socket of an electrical wiring of the sensor of the OZh (A) level, weaken a collar (B) and disconnect a hose from a broad tank.
|
- Uncover a broad tank and completely turn out the screw for pumping of the cooling system.
|
- Release an overlay of fastening of a broad tank from clamps.
|
|
- Delay a broad tank back and remove a ventilation hose.
|
|
- Release a broad tank from the lower fixing pads and remove the movement up.
|
|
At installation holders have to enter grooves on a fan casing. |
- Installation is made upside-down. In conclusion pump over the cooling system and check it for tightness.
|
|
Models with the M57 engine
|
- Close the generator to prevent hit on it motive oil, fuel or OZh.
- Lower cooling liquid (see the Section Replacement of Cooling Liquid of the Head Nastroyki and routine maintenance of the car).
|
- Disconnect perepuskny a hose (1). Extend a cap the movement up and weaken a collar (2) fastenings of a hose for removal of air. Weaken a collar (3) and disconnect a hose.
|
- Wring out a clamp (4) and remove a broad tank (5) the movement up. Separate the OZh level sensor electrical wiring socket on the lower party of a broad tank.
|
At installation replace a collar (2) and to rearrange the sensor on a new broad tank. |
|
|
Models with the M67 engine
|
- Lower OZh (see the Section Replacement of Cooling Liquid of the Head Nastroyki and routine maintenance of the car).
|
- Take rivets (1), uncover (2), squeeze the fixing pads of an arm (3) and remove it the movement up.
|
|
- Lift a casing (1) of the fan by means of the screw-driver (2) over the screw (3) pumpings of the cooling system. Remove a broad tank (4) the movement back.
|
|
- Cut a collar (1) and disconnect a hose (2) ventilations.
|
|
At installation use a new collar (1). |
|
- Weaken a collar (1) of fastening of a water hose (2) and disconnect it from a broad tank (4). Separate the socket (3) sensors of the OZh level.
|
- Installation is made upside-down. If necessary rearrange the OZh level sensor on a new broad tank.
|
|
|
|