9.5. Removal and installation of the PNP sensor
|
The description on the example of AT A5S 440Z is given below. |
|
- Remove the back panel of protection of auxiliary units of the engine.
- Remove the left and right thermofilters.
- Holding the tightening plug (1), give a nut (2).
|
At installation adjust the selector lever. |
- The screw-driver take out a lock plate and pull out draft (2).
- Prop up AT devices No. No. 00 2 030/24 5 301/24 00 250.
|
- Turn out bolts approximately on 10 mm and lower AT at this size.
|
|
- Give a nut (1) and remove the balance weight (2) of the control unit.
|
|
- Turn out bolts and remove the PNP (1) sensor from a control unit balance weight axis.
|
|
- Separate the socket (1) and take out the socket. Take the socket (2) of a fixing corner, unclench clips on the pallet of a case and take from them a cable.
|
|
|
|
|
|